Home Page LinkConstruction ServicesTechnical ServicesContact UsSafety InformationAbout DCI

 

Tower Inspection & Maintenance

Loose hardware, missing hardware, rust or even damaged antenna components can cause a headache for your communication towers and communication systems.  Tower Inspections and/or Maintenance is an issue a lot of companies either overlook of consider an unnecessary expense.

However, in our experience, regular tower inspections and maintenance can help avoid the sometimes extreme costs of tower repairs should a failure occur with the tower itself or with your antenna systems.  Early detection is the key in avoiding any disruption to your communication flow.

Even the best tower installers have been discovered to have missed tightening a nut or two, and many times we have discovered short cuts taken to save time or money have failed.  As a highly reputable company in the microwave industry, we provide you an honest detailed report complete with photographs to give you an accurate status of your tower systems.

Regular inspection and maintenance is a bonus to your system, but how often you should perform these functions is entirely up to you.  We recommend that you do a routine check at least every 24 months, but often find it better to use a 12 month interval.  Severe Storms can cause havoc on your tower at any given time, and we strongly suggest that you perform a visual check of your communication site if such a storm occurs.  Loss in radio signals, loss in pressure of waveguide systems, waveguide or coax slapping against the tower, or even components found on the ground that should be found on the tower only should be cause to perform a tower inspection to correct any damage from the storm.

Important Items We Inspect:

  • Site Conditions

    • Building/Shelter

    • Waveguide Bridge

    • General Condition of Site

    • Fencing

  • Tower Structure

    • Foundations

    • Tower Plumb/Straight

    • Galvanizing Condition

    • Paint Condition

    • Climbing Device

    • Tower Hardware

    • Tower Members

    • Grounding

  • Tower Guying System

    • Anchors and Anchor Foundations

    • Guy Cables

    • Guy Tension

    • Grounding

  • Tower Lighting Systems

    • Lamp Illumination

    • Conduit Runs

    • Controller Box

    • Beacon/Obstruction Lights

    • Power Outlets

    • Photo Cell Operation

  • Antenna Details

    • Model/Serial/Size/Location

    • Polarization/Azimuth

    • Centerline

    • Hardware Condition

    • Paint Condition

    • Radome/HP Cover Condition

    • Stiff Arm Attachments

  • Waveguide/Coax Details

    • Type/Length

    • Grounding

    • Supports

    • Overall Condition (Kinks, Bends, Protection, Weatherproofing)

  • Passive Repeaters

 

 

 

 

 

 
 
 
 

Phone : 503-364-4750          Fax : 503-364-5115          PO Box 4150          Salem, OR 97302-8150